What did this study find?

Nineteen males aged nine to eighteen with high-functioning autism received continuous theta-burst stimulation. Older participants showed longer-lasting changes in corticospinal excitability, not demonstrated clinical improvement. This small, uncontrolled physiological study supports tolerability of the studied protocol, not clinical efficacy or PEMF safety. More than one-third of participants showed paradoxical facilitation rather than the expected suppression.

What are the details of this record?

Full citation
Oberman LM, Pascual-Leone A, Rotenberg A. Modulation of corticospinal excitability by transcranial magnetic stimulation in children and adolescents with autism spectrum disorder. Front Hum Neurosci. 2014;8:627.
Journal
Frontiers in Human Neuroscience
Authors
Oberman LM, Pascual-Leone A, Rotenberg A
Study design
Uncontrolled physiological study
Sample size and population
19 males aged 9-18 with ASD
Evidence grade
Grade C on the BioReg grading scale
Reported findings
Following 40 seconds of continuous theta-burst stimulation, older participants had longer-lasting corticospinal-excitability after-effects; more than one-third showed paradoxical facilitation. Findings support tolerability of the studied rTMS protocol but do not establish clinical benefit or PEMF safety.
Funding and conflicts of interest
The paper's conflict of interest statement reads: "Alvaro Pascual-Leone serves on the scientific advisory boards for Nexstim, Neuronix, Starlab Neuroscience, Neuroelectrics, and Neosync; and is listed as an inventor on several issued and pending patents on the real-time integration of transcranial magnetic stimulation (TMS) with electroencephalography (EEG) and magnetic resonance imaging (MRI). Alexander Rotenberg is listed as an inventor on a patent for apparatus and method of use of TMS in epilepsy. He is a co-founder of Neuromotion Inc."

A positive PEMF study is not evidence for a specific device unless the signal parameters studied, frequency, intensity, waveform, and exposure duration, are reasonably comparable to what that device produces. Where this record does not list those parameters, the source report did not publish them. See the grading methodology. Library last reviewed 2026-08-27.