What did this study find?
This 2024 pilot study treated 20 children with autism spectrum disorder with extremely low frequency electromagnetic fields for 15 weeks and compared scores before and after treatment. Receptive and expressive language scores and externalizing problems improved significantly. The study had no control group and no blinding, and it did not measure inflammation, so the changes cannot be attributed to the treatment.
What are the details of this record?
- Full citation
- Pietramala K, Greco A, Garoli A, Roblin D. Effects of Extremely Low-Frequency Electromagnetic Field Treatment on ASD Symptoms in Children: A Pilot Study. Brain Sci. 2024 Dec 22;14(12):1293. doi:10.3390/brainsci14121293.
- Journal
- Brain Sciences
- Authors
- Pietramala K, Greco A, Garoli A, Roblin D
- Study design
- Uncontrolled pilot study
- Sample size and population
- 20 children aged 2 to 13 with ASD
- Evidence grade
- Grade C on the BioReg grading scale
- Reported findings
- Uncontrolled pilot in 20 children over 15 weeks, comparing scores before and after treatment. Significant improvements in receptive language (PPVT-4 from 74.07 to 90.40) and expressive language (EOWPVT-4 from 84.17 to 90.50), and reductions in externalizing problems. No control group and no blinding; inflammation was not measured.
- Funding and conflicts of interest
- The paper's conflict of interest statement reports that one author, Alessandro Greco, was employed by S.I.S.T.E.M.I. srl, the manufacturer of the SEQEX device used in the study.
- PubMed
- PMID 39766492
- Related categories
- Autism Spectrum (category grade A- (TMS and tDCS) / C to B+ (TMS) / C (PEMF))
A positive PEMF study is not evidence for a specific device unless the signal parameters studied, frequency, intensity, waveform, and exposure duration, are reasonably comparable to what that device produces. Where this record does not list those parameters, the source report did not publish them. See the grading methodology. Library last reviewed 2026-08-27.